Count by Chassis Types Problem:. However... nothing is ever straight forward. SCCM Device Collections based on Enclosure Type SCCM Create Collections for Laptops In Configuration Manager a query is a specific set of instructions that extract information about a defined set of objects. For server Chassis Type: 23 Below is the collection to list all the computers which are laptops which fall in above Chassis type. Because this … Access type: Read-only Keep reading below! Reply to this topic; Start new topic; Recommended Posts. This property is inherited from CIM_PhysicalPackage. It turns out that just because there's a long list of different chassis types to choose from, the manufactures decided they would. SCCM Create Collections for Laptops In Configuration Manager a query is a specific set of instructions that extract information about a defined set of objects. This blogpost can be found here: How to add devices to different OU’s during deployment. So I was thinking the other day if there might be a better way and I remembered that WMI stores the chassis type in Win32_SystemEnclosure and that SCCM gathers this. Reply. Why do you need this report? SCCM 2007 R2 – Chassis Types and query based Collections One of the fundamental things you need to do with any SCCM installation and deployment, you need to get the basics right. I can't find any literature on the way this is actually defined, it seems to be up to the manufacturer and how they define it. Basically I want to use this chassis type in SCCM to define some settings but I want to be positive that I can count on it.
Inventory - Chassis Type. All these values are from SQL table called SMS_G_System_SYSTEM_ENCLOSURE .If you are looking to create SCCM report,you can create using Views( v_GS_SYSTEM_ENCLOSURE ). By Joe Parker - August 04, 2016 Read more Lenovo Updates Catalog V3 for SCCM. Load more... Post a Comment. Powered by Blogger Theme images by Airyelf (c) Lenovo 2016. Thus, the following Chassis Types are typical to: laptops: 8 , 9, 10, 11, 12, 14, 18, 21. desktops: 3, 4, 5, 6, 7, 15, 16. servers: 17,23. The SQL Query below is a tidied up version that at least makes it reasonably easy to read. Followers 0. You can create queries and store them in the Configuration Manager 2012 site database. You can create queries and store them in the Configuration Manager 2012 site database.
32 - Detachable. According to a post on Lenovo's deployment blog, the new SMBIOS 3.0 Specification is adding additional chassis types: 30 - Tablet. Get it here! Qualifiers: Units ("inches") Height of the physical package—in inches. Solution: Count by Chassis Types. WScript.Echo "Computer chassis type: " & strCaseType Next Hope you find it useful. 31 - Convertible. Access type: Read-only. MDT, SMS, SCCM, Current Branch &Technical Preview ; Configuration Manager 2012 ; Inventory - Chassis Type Sign in to follow this . June 2018’s free System Center Configuration Manager (SCCM) report is Count by Chassis Types. The Count by Chassis Types dashboard puts the … Data type: boolean. For instance, in this day and age what's the chassis type difference between: Mini Tower, Low Profile Desktop, Space-Saving etc. :-) Reply Delete.
By Joe Parker - June 16, 2020 Read more New … The final version of a WMI filter looks like this: select * from Win32_SystemEnclosure where ChassisTypes = "8" or ChassisTypes = "9" or ChassisTypes = "10" or ChassisTypes = "11" or ChassisTypes = "12" or ChassisTypes = "14" or ChassisTypes = "18" or … Solution: Count by Chassis Types. This time I want to create collections on PCSystemType. This property is inherited from CIM_Chassis. Chassis Types and query-based Collections (part 2) Last month I published a blogpost about WMI queries on PCSystemType. All these values are from SQL table called SMS_G_System_SYSTEM_ENCLOSURE.If you are looking to create SCCM report,you can create using Views (v_GS_SYSTEM_ENCLOSURE).
Queries are those basic building blocks which everything else in SCCM is based on. Height. The Count by Chassis Types dashboard puts the 24 System Enclosure WMI classes into two... PC Types … It turns out that just because there's a long list of different chassis types to choose from, the manufactures decided they would. Data type: real32. This can be used during a task sequence deployment to decide if the system is a desktop or laptop (for example). MMS2019 Popular The Think BIOS Config tool.
The Free SCCM Report is Count by Chassis Types Problem:. For server Chassis Type: 23 Below is the collection to list all the computers which are laptops which fall in above Chassis type. ObjFSO.FilesCopy Permission Denied from SCCM Office Deployment Toolkit for APP-V Issue; Unable ... ConfigMgr 2007: How to inventory mapped drives - T... Dear Xbox 360 makers SCCM SQL Count of chassis type February ( 2 )
By j1mmyd3an, November 8, 2012 in Configuration Manager 2012. Therefore when I expected to see lots of "Desktop" what I did see was "Desktop", "Pizza-Box", "Mini-Tower" etc. Add comment. Problem: There are 24 different System Enclosure WMI classes and there isn’t a built-in SCCM report that will help you figure out the number of desktops, laptops, servers or virtual machines (VMs) in your environment. Replies. Amount of heat that is generated by the chassis in BTU/hour. HotSwappable.